危废暂存间建设标准规范主要包括以下几点:
The construction standards and specifications for hazardous waste temporary storage rooms mainly include the following points:
独立密闭:危废暂存间应独立设置,并采用密闭结构,上锁防盗。
Independent and sealed: The hazardous waste temporary storage room should be set up independently and adopt a sealed structure, locked and anti-theft.
设施:内部需设有照明设施和观察窗口。
Safety facilities: There should be safety lighting facilities and observation windows inside.
地面与墙面:地面应进行防渗处理,墙面和地面应使用与危险废物相容的材料建造,并涂有少2mm厚度的环氧树脂以防止渗漏和腐蚀。
Ground and walls: The ground should be treated with anti-seepage measures, and the walls and floors should be constructed using materials compatible with hazardous waste and coated with at least 2mm thick epoxy resin to prevent leakage and corrosion.
防泄漏措施:门口内侧应设立围堰,防止泄漏物扩散。
Leakage prevention measures: A cofferdam should be set up on the inside of the entrance to prevent the spread of leaked materials.
标识与管理:门口需张贴危险废物标识和信息板,内部应张贴企业危险废物管理制度。
Identification and management: Hazardous waste signs and information boards should be posted at the entrance, and the company's hazardous waste management system should be posted internally.
双人双锁制度:危险废物贮存间需按照“双人双锁”制度管理,确保只有授权人员可以进入。
Double person and double lock system: Hazardous waste storage rooms must be managed according to the "double person and double lock" system to ensure that only authorized personnel can enter.
分区与标签:危废暂存间内应根据废物种类进行分区,并在各区域明显位置设置标志牌。
Zoning and labeling: The hazardous waste temporary storage room should be divided according to the type of waste, and signs should be placed in prominent positions in each area.
危废分类存放:不同种类和化学性质不相容的危险废物应分开存放,并有适当的隔离措施。
Classification and storage of hazardous waste: Hazardous waste of different types and incompatible chemical properties should be stored separately with appropriate isolation measures.
泄漏收集装置:存放液体危废的暂存间内必须有泄漏液体收集装置,如托盘、导流沟或收集池。
Leakage collection device: There must be a leakage liquid collection device in the temporary storage room for storing liquid hazardous waste, such as a tray, diversion ditch, or collection pool.
气体净化装置:存放具有挥发性气体的暂存间内必须有导出口及气体净化装置。
Gas purification device: There must be an outlet and gas purification device in the temporary storage room where volatile gases are stored.
台账记录:建立危废产生台账,记录危废的种类、数量、时间及负责人员等信息。
Ledger record: Establish a hazardous waste generation ledger, recording information such as the type, quantity, time, and responsible personnel of hazardous waste.
清运与贮存限制:危废暂存间应及时清运贮存的危险废物,并实时监控贮存量,防止超过规定限额。
Clearance and storage restrictions: The hazardous waste storage room should promptly clear and store hazardous waste, and monitor the storage capacity in real time to prevent exceeding the prescribed limit.
消防与环境噪声控制:设置消防设施,并符合环境噪声控制指标,配备相应的报警装置。
Fire protection and environmental noise control: Install fire protection facilities that comply with environmental noise control indicators and are equipped with corresponding alarm devices.
贮存期限:危险废物贮存不得超过一年,超过期限需报部门审批。
Storage period: Hazardous waste storage shall not exceed one year, and approval from the environmental protection department is required if the storage period is exceeded.
以上标准规范旨在确保危险废物在暂存过程中的性与环境友好性,防止对环境和人体健康造成危害。
The above standards and specifications aim to ensure the safety and environmental friendliness of hazardous waste during temporary storage, and prevent harm to the environment and human health.